Fish Farming UV Water Treatment Disinfection Equipment


Product name: Ultraviolet Water Sterilizer

详情介绍:

Introduction

UV system is designed to treat flows ranging from 2-1136m3/h, and can be used for germicidal disinfection, ozone destruction, TOC reduction, and liquid sugar disinfection. It is suitable for indoor installation in locations including food and beverage processing plant, cosmetics and pharmaceuticals manufacturing, hospitals and laboratories, water treatment and community drinking water systems.


Compared with other disinfection form, UV sterilizer has the following advantages:

1,High efficient sterilization: normally kill 99%-99.9% bacteria within 1 to 2 seconds.

2, Broad spectrum: UV rays has broadest spectrum, can kill almost all bacteria and virus.

3, No secondary pollution: don't add any chemical agent, so cannot create secondary pollution to 

water and ambient environment, do not change any ingredients in water.

4, Safe and reliable to operate: traditional disinfection technology such as adopting chloride or 

ozone,whose disinfection agent itself are highly toxic and flammable material. While UV sterilizer 

has no such potential safety hazard .

5, Low maintenance fee: UV sterilizer occupies a small area, structure requirement is simple, so 

total investment is smaller. Lower in operation, it costs only half than that chlorine disinfection in  water treatment.

Principle of Operation
UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.

Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.

Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels

Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰


Specifications:

model

capacity

Power

inlet-outlet

reactor

panel

Anchor

G weight


m³/hour

watt

mm

L×W×H

cm

screw

Kg

YLCn-005

0.3

16

1/2″

30×6×11

without

without

5

YLCn-008

1

25

1/2″

47×6.3×11

without

without

10

YLCn-050

2

40

1″

100×9×20

Φ8.9×25

(d×L)

69×4×Φ1

25

YLCn-150

6

80

1+1/4″

100×11×23


69×4×Φ1

30

YLCn-200

8

120

1+1/2″

100×15.9×30

Φ8.9×45

(d×L)

69×7×Φ1

35

YLCn-300

12

160

2″

100×15.9×32


69×7×Φ1

40

YLC-050

2

40

DN25/1″

100×8.9×30

25×30×12

(W×H×D)

60×4×Φ1

45

YLC-150

6

80

DN32/11/4″

100×10.8×30


60×4×Φ1

50

YLC-200

8

120

DN40/11/2″

100×15.9×40


60×7×Φ1

60

YLC-300

12

160

DN50/2″

100×15.9×40


60×7×Φ1

70

YLC-360

15

200

DN65/21/2″

100×15.9×40


60×7×Φ1

120

YLC-500

20

240

DN65/21/2″

100×21.9×50


60×11×Φ1.2

130

YLC-600

25

280

DN80/3″

100×21.9×50


60×11×Φ1.2

140

YLC-700

30

320

DN100/4″

100×21.9×50


60×11×Φ1.2

150

YLC-1000

40

360

DN100/4″

100×21.9×50


60×11×Φ1.2

160

YLC-1200

50

400

DN125/5″

100×21.9×50


60×11×Φ1.2

180

YLC-1500

60

420

DN150/6″

170×27.3×57


120×16×Φ1.4

210

YLC-2000

80

560

DN150/6″

170×27.3×57


120×16×Φ1.4

220

YLC-2500

100

700

DN150/6″

170×27.3×57

60×128×30

(W×H×D)

120×16×Φ1.4

275

YLC-3000

125

840

DN150/6″

170×27.3×57


120×16×Φ1.4

300

YLC-4000

150

1120

DN200/8″

173×32.5×65


120×20×Φ1.6

325

YLC-5000

200

1400

DN200/8″

173×37.7×72


120×22×Φ1.6

350

YLC-7000

300

2100

DN250/10″

175×42.6×80


120×24×Φ2.0

400

YLC-10K

400

2520

DN250/10″

176×52.9×95

60×150×40

(W×H×D)

120×22×Φ2.2

475

YLC-15K

600

3080

DN300/12″

176×78×110


120×32×Φ2.4

600

YLC-20K

800

3920

DN350/14″

Designated

Designated

Designated

Designated

YLC-25K

1000

4760

DN350/14″

Designated

Designated

Designated

Designated

UV disinfection system Application

1. Food processing industry, including juices, milk, drinks, beer, practical oil and canned food.
2. Electronic industry.
3. Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4. Households building, residential, office buildings, hotels, restaurants, water factories.
5. Purification and disinfection of shellfish, fish cleaning and disinfection
6. Military camp, field water supply system
7. Urban wastewater disinfection.
8. Swimming pool, other recreational water disinfection
9. Thermal power, nuclear power plant industrial, central air conditioning system cooling water.
10. Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
11. Sea water, fresh water breeding, aquaculture water
12. Agricultural water disinfection

FAQ:

Q. How do ultraviolet ("UV") sterilizers work? 
A. UV sterilizers work by exposing water to powerful germicidal ultraviolet light. DNA and protein links in bacteria are destroyed by exposure to this light. 
Q. Does the water become radioactive by this radiation? 

A. No. No radiation residual or any chemical residual is left in the water as a result of the UV rays.

Q. Do these systems come in different sizes? 

A. Yes. The size of the systems is directly proportional to the flow rate of the water in gallons per minute. The higher the flow rate, the larger the system and lamp. 
Q. Does the water have to sit in the UV sterilizer to be disinfected? 
A. No. If the system is sized correctly, the water is disinfected as it flows through. 
Q. What if the water flows faster than is allowed through the system? 
A. If the flow rate exceeds the design flow rate of the UV sterilizer, then there is a possibility that the water will not be properly disinfected. It is important to use a flow restrictor so that the flow rate cannot be exceeded. 
Q. How long does the lamp last? 
A. The lamps last approximately 10,000 hours. That is why we recommend replacement approximately every 12 - 14 months of continuous operation. After this period, the lamp itself becomes solarized and blocks the rays form entering the water. 
Q. Are these systems bigger energy users? 
A. No. The 12 gallon per minute model, for instance uses only 39 watts, about half the amount an ordinary light bulb uses.
Q. My water is sometimes cloudy. Is that a problem? 

A. Yes. The water that enters the ultraviolet sterilizer must be absolutely clear and have a turbidity of less than 1 NTU. If your water is cloudy, then it must be pretreated. 