Ultraviolet Water Disinfection System For Wastewater Treatment
Product name: UV water disinfectio
Ultraviolet Water Disinfection System For Wastewater Treatment
Product name: UV water disinfectio
Product Description
Ultraviolet sterilizers use ultraviolet (UV) light to disinfect system water, destroying any waterborne pathogens. Unlike chlorine or bromine, UV sterilization leaves no toxic residuals in the water which may be harmful to the animals.
The sterilizer assembly consists of ultraviolet sterilizing lamp, quartz sleeve, and housing.
How Does UV Sterilisation Work?
Ultraviolet sterilization (UV) is a process to eliminate biological contamination, namely parasite fungus and bacteria. Two types are commercially available, both in tube size. Generally the one containing a wet bulb -at which the water passes directly past the UV bulb- is cheaper.
The other type available has a protective quartz tube around the bulb (dry bulb). The latter has the advantage of easier cleaning, since debris and slime will eventually settle on the bulb, or quartz surrounding. Both work on the same principle.
UV sterilization exposes the contaminants with a lethal dose of energy in the form of light. The UV light will alter the DNA of the pathogens, by virtually gluing DNA molecules together. The changed cell structure prevents the organism from reproducing itself (sterilization), therefore eliminating it.
Features:
* Process does not change pH, taste, odour or chemical composition of fluid being disinfected.
* A maximum of 99.9%+ micro-organism 'kill' is achieved.
* Non-wetting Teflon? eliminates fouling and thus the need for the wiping and constant cleaning is avoided.
* Main Chamber is of SS, water passes through SS inlet/outlet and headers and Teflon. Water has
no contact with main SS Radiator Chamber.
* Maintains the natural qualities and taste of water, intact.
* Works instantly.
* There are no moving parts inside the System, hence no wear & tear to any parts.
* Unit works continuously.
* Absolutely 'Maintenance Free'.
* Simple to install and operate.
* Easy replacement of UV lamps.
* UV Lamps are positioned in such a way inside the System, that ensures penetration of UV rays
from all sides.
* chemically inert, and can withstand high pressure and high temperature.
* excellent transmitter of UV.
* Not at all prone to inner corrosion, dirt collection or contamination.
* Complete separation of fluid system and electrical circuits, resulting in improved reliability and safety.
* Simpler, safer and cheaper than alternative disinfection methods.
Specifications:
model | capacity | Power | inlet-outlet | reactor | panel | Anchor | G weight |
m³/hour | watt | mm | L×W×H | cm | screw | Kg | |
YLCn-005 | 0.3 | 16 | 1/2″ | 30×6×11 | without | without | 5 |
YLCn-008 | 1 | 25 | 1/2″ | 47×6.3×11 | without | without | 10 |
YLCn-050 | 2 | 40 | 1″ | 100×9×20 | Φ8.9×25 (d×L) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4″ | 100×11×23 | 69×4×Φ1 | 30 | |
YLCn-200 | 8 | 120 | 1+1/2″ | 100×15.9×30 | Φ8.9×45 (d×L) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2″ | 100×15.9×32 | 69×7×Φ1 | 40 | |
YLC-050 | 2 | 40 | DN25/1″ | 100×8.9×30 | 25×30×12 (W×H×D) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/11/4″ | 100×10.8×30 | 60×4×Φ1 | 50 | |
YLC-200 | 8 | 120 | DN40/11/2″ | 100×15.9×40 | 60×7×Φ1 | 60 | |
YLC-300 | 12 | 160 | DN50/2″ | 100×15.9×40 | 60×7×Φ1 | 70 | |
YLC-360 | 15 | 200 | DN65/21/2″ | 100×15.9×40 | 60×7×Φ1 | 120 | |
YLC-500 | 20 | 240 | DN65/21/2″ | 100×21.9×50 | 60×11×Φ1.2 | 130 | |
YLC-600 | 25 | 280 | DN80/3″ | 100×21.9×50 | 60×11×Φ1.2 | 140 | |
YLC-700 | 30 | 320 | DN100/4″ | 100×21.9×50 | 60×11×Φ1.2 | 150 | |
YLC-1000 | 40 | 360 | DN100/4″ | 100×21.9×50 | 60×11×Φ1.2 | 160 | |
YLC-1200 | 50 | 400 | DN125/5″ | 100×21.9×50 | 60×11×Φ1.2 | 180 | |
YLC-1500 | 60 | 420 | DN150/6″ | 170×27.3×57 | 120×16×Φ1.4 | 210 | |
YLC-2000 | 80 | 560 | DN150/6″ | 170×27.3×57 | 120×16×Φ1.4 | 220 | |
YLC-2500 | 100 | 700 | DN150/6″ | 170×27.3×57 | 60×128×30 (W×H×D) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6″ | 170×27.3×57 | 120×16×Φ1.4 | 300 | |
YLC-4000 | 150 | 1120 | DN200/8″ | 173×32.5×65 | 120×20×Φ1.6 | 325 | |
YLC-5000 | 200 | 1400 | DN200/8″ | 173×37.7×72 | 120×22×Φ1.6 | 350 | |
YLC-7000 | 300 | 2100 | DN250/10″ | 175×42.6×80 | 120×24×Φ2.0 | 400 | |
YLC-10K | 400 | 2520 | DN250/10″ | 176×52.9×95 | 60×150×40 (W×H×D) | 120×22×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12″ | 176×78×110 | 120×32×Φ2.4 | 600 | |
YLC-20K | 800 | 3920 | DN350/14″ | Designated | Designated | Designated | Designated |
YLC-25K | 1000 | 4760 | DN350/14″ | Designated | Designated | Designated | Designated |
UV Disinfection Systems Application
1. Food processing and industrial water disinfection
2. Hospitals, various laboratory water disinfection, and high levels of pathogenic water disinfection
3. Municipal water
4. Biochemical pharmaceutical, cosmetics production water disinfection
5. Aquatic products processing water disinfection
6. Swimming pool water disinfection
7. Seawater, freshwater aquaculture breeding water disinfection
8. Ultra-pure water for electronic industry, and so on
Comparison of disinfection methods:
Factors to be considered | Liquid chlorine disinfection | Chlorine dioxide disinfection | Ozone disinfection | UV disinfection | |
Time to be processed | 30 min | ≤30min | 5~10min | 30~60s | |
Dosage (mg/l) | 2~20 | 5~10 | 1~3 | 30~40 | |
Efficiency of inaction bacteria | High | High | High | High | |
Efficiency of bacteria and viruses | Lower middle | Middle | High | High | |
Water quality factors | More easily affected by PH and temperature | More easily affected by PH and temperature | Less affected by PH and temperature | Less affected by PH and temperature | |
Operation complexity | Simple to middle | Middle | Complicated | Simple to middle | |
Economical efficiency | Operation cost | Lower middle | Middle | Above the average | Lower middle |
Area | Large | Less | Small | Small | |
Maintenance work | Large | Less | Large | Small | |
Adverse impact | Safety during transportation | Yes | Yes | No | No |
Site security | Very high | Middle | Middle | Smaller | |
Poisoning against the fishes and large invertebrates | Toxic | Poisonous | No | No | |
Whether there exists the toxic by product | Yes | Exist in small quantity | Yes | No | |
Disposal of the cleaning agents | No | No | No | Have | |
Whether or not to increase the content of the soluble solid | Yes | Yes | No | No | |
Corrosively | Yes | Yes | Yes | No | |
High energy consumption | No | No | Yes | Yes |